SYNN0101MNXX104 |
SYNN0101MNXX105 |
SYNN0101MNXX106 |
SYNN0101MNXX204 |
SYNN0102MNXX104 |
SYNN0102MNXX105 |
SYNN0102MNXX106 |
SYNN0103MNXX104 |
SYNN0103MNXX105 |
SYNN0103MNXX106 |
SYNN0107MNXX104 |
SYNN0301MNXX104 |
SYNN0301MNXX105 |
SYNN0301MNXX106 |
SYNN0301MNXX204 |
SYNN0302MNXX104 |
SYNN0302MNXX105 |
SYNN0302MNXX106 |
SYNN0302MNXX204 |
SYNN0302MSXX104 |
SYNN0303MNXX104 |
SYNN0303MNXX105 |
SYNN0303MNXX106 |
SYNN0307MNXX104 |
SYNN0307MNXX204 |
SYNN0307MNXX205 |
SYNN0307MNXX206 |
SYNN0310MNXX104 |
SYNN0601MNXX104 |
SYNN0601MNXX105 |
SYNN0601MNXX106 |
SYNN0601MNXX116 |
SYNN0601MNXX204 |
SYNN0602MNXX102 |
SYNN0602MNXX104 |
SYNN0602MNXX105 |
SYNN0602MNXX106 |
SYNN0602MNXX109 |
SYNN0602MNXX116 |
SYNN0602MNXX204 |
SYNN0603MNXX104 |
SYNN0603MNXX105 |
SYNN0603MNXX106 |
SYNN0607MNXX104 |
SYNN0607MNXX204 |
SYNN0610MNXX104 |
SYNN0610MNXX204 |
SYNN0636MNXX104 |
Non Sterile Syringe Filters, Syringe Filters, Filters
- High retention efficiency
- 16 Channels for minimum back pressure
- Hydrophilic, having wide chemical compatibility
- HPLC certified for low levels of UV absorbing extractables
- Heat sealed to ensure ‘no leaching’
- No initial flushing required
- Sample filtration for HPLC and other critical instruments
- Filtration of organic solvents and chemicals
Construction |
Pore size |
0.1µm, 0.2µm, 0.45µm, 0.8µm, 1.2µm, 5µm |
Media |
Nylon-66 Membrane |
Diameter |
|
Inlet |
Female luer-lock |
Outlet |
Male luer slip |
Housing |
Polypropylene |
Operational |
Max. Operating Temperature |
55 °C |
Max. Differential Pressure |
75 psi @ 25° C |
Burst Pressure |
>12kg/cm² |
Hold-up Volume(with air purge) |
|
Clean Water Flow Rate @ 20 psi (0.2µm) |
> 0.5 ml/min |
> 6 ml/min |
> 40 ml/min |
|
Clean Water Flow Rate @ 20 psi (0.45µm) |
> 1 ml/min |
> 10 ml/min |
> 80 ml/min |
|
Sample Volume |
|
Assurance |
Fiber Release |
Complies with USFDA CFR Title 21, Part 210.3(b)(6) and do not requires any initial Flushing. |
Non Fiber Releasing |
Passes test as per USP and comply with USFDA 21 CFR Part 211.72 for fiber release. |
Particle Release |
The filtrate Complies with USP <788> test for particulate matter in injectables. |
Indirect Food Additive |
The plastic housing material complies with the requirements of USFDA CFR Title 21 Part 177.1520. |
Oxidizable Substances |
Within limits as specified in USP |
Quality Management System |
ISO-9001 Certified |
Type | Type | Code | Nylon-66 Membrane Syringe Filters | SYNN | | Size | Diameter | Code | 4mm | 01 | 13mm | 03 | 25mm | 06 | | Pore Size | Pore Size | Code | 0.1µm | 36 | 0.2µm | 01 | 0.45µm | 02 | 0.8µm | 03 | 1.2µm | 10 | 5µm | 07 | | Inlet/Outlet | | Code | Female luer-lock | M | Male luer slip | N | | | Sterility
| | Code | Non Sterile | 1
| | Pack Size | Pack Size | Code | 100 | 04 | 1000 | 06 | | |
Example :