- Absolute retention
- 100% integrity tested
- Low protein binding
- Very low hold up volume in filters
- High flow rates
- Serial construction with prefilter for higher throughput with fouling streams
- Bioburden maintained below 1000 cfu/device
- Endotoxin level certified to be <0.25 EU/ml
- Widest range of end connections
- Products available for total scalability from a few ml to thousands of liters
- Total traceability through unique serial number for each filter
- Individual certificate of quality for each device
- Sterilizable by EO gas or autoclaving
Sterile Filtration of:
- Cell culture media
- Cell culture media containing serum
- Media additives
- pH adjusters
- Final product concentrates
Bioburden Reduction/ Particulate Removal:
- Buffers
- Centrifuge supernatants
- Clarified cell lysates
Construction | |||
Membrane | Hydrophilic PES | ||
Final Filter Pore Size | 0.2µm | ||
Prefilter Pore Size | 0.8 µm, 0.65µm, 0.45µm | ||
Body and Core | Polypropylene | ||
Size | |||
Size |
|
||
Effective Filtration Area (Nominal) |
|
||
Dimension (End to End) – Female Luer Lock Inlet/ Male Luer Slip |
|
||
Dimension (End to End) – ¾” Sanitary Flange Inlet I/O |
|
||
Dimension (End to End) – ¼” SHB |
|
||
Operational Radius (with Vent/ Drain) |
|
||
Integrity Testing / Retention | |||
Bubble Point | > 50psi (3.52Kg/cm²) with Water | ||
Microbial Retention | LRV >7 for Brevundimonas diminuta (ATCC 19146) per cm² | ||
Operational | |||
Max. Operating Temperature |
|
||
Max. Differential Pressure |
|
||
Hold-up Volume(with air purge) |
|
||
pH Compatibility | Compatible with pH range of 1-10 | ||
Sterilization By Gas | Sterilizable by Ethylene Oxide | ||
Sterilization By Autoclave | Autoclavable at 125°C for 30 minutes, 25 cycles and it cannot be in-line steam sterilized | ||
Shelf Life | 3 years after EO sterilization | ||
Assurance | |||
Toxicity | Passes Bioreactivity test, In Vivo, as per USP <88> for Class VI plastics | ||
Cytotoxicity | Passes Biological Reactivity Tests, In Vitro, USP <87> for cytotoxicity | ||
Bacterial Endotoxin | Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test as per USP <85> | ||
Bioburden | Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018 | ||
Non Fiber Releasing | Passes test as per USP and comply with USFDA 21 CFR Part 210.3(b)(6) for fiber release | ||
Indirect Food Additive | All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520 | ||
Extractables with WFI | Passes NVR test as per USP <661> | ||
Good Manufacturing Practice | These products are manufactured in a facility which adheres to Good Manufacturing Practices. | ||
Oxidizable Substances | Within limits as specified in USP <1231> | ||
TOC/Conductivity at 25 °C | Meets the WFI requirements of USP for TOC <643> and Conductivity <645> after a 500ml flush Integrity Testing/ Retention Size Assurance Operational DST | ||
Quality Management System | ISO-9001 Certified | ||
USFDA | DMF No. 015554 |
0.2µm AseptiCap® KL/KS (25 mm)
|
|
|
|
|
|
|
|
* 0.45µm upstream is available with 0.2µm pore size only
**Female Luer Lock is available as Inlet only
***Male Luer Slip is available as Outlet only
Example :
IKSX | 06 | 01 | MN | X | X | 1 | 04 |
Example for Non Sterile: IKSX0601MNXX104 Example for EO Sterile: IKSX0601MNXX204
0.2µm AseptiCap® KL/KS (50 mm)
|
|
|
|
|
|
|
|
* 0.45µm upstream is available with 0.2µm pore size only
**¼” Stepped Hose Barb and ¾” Sanitary Flange are available in filters with vent only
***¼” Single Step Hose Barb and Female luer lock is available in filters without vent only
Example :
VKSX | 10 | 01 | SS | X | X | 1 | 02 |
Example for Non Sterile: VKSX1001SSXX102 Example for EO Sterile: VKSX1001SSXX202