0.2μm AseptiPrime® KS Small
mdi AseptiPrime® KS are sterilizing grade PES membrane capsule filters specially designed for very high throughput.
The special asymmetric pre-filter membrane layer with high asymmetric proportion offers high loading and volume handling capacities to provide enhanced protection to the final membrane layer.
These are available in a wide range of sizes and end connections tosuit a multitude of sterilization applications in biopharmaceuticals for process development, pilot scale and production batch sizes.
AseptiPrime® KS filters meet key process requirements such as absolute retention, high protein recoveries and low extractables.
- Absolute retention
- 100% integrity tested
- Low protein binding
- Very low hold up volume in filters
- High flow rates
- Serial construction with prefilter for higher throughput with fouling streams
- Bioburden maintained below 1000 cfu/device
- Endotoxin level certified to be <0.25 EU/ml
- Widest range of end connections
- Products available for total scalability from a few ml to thousands of liters
- Total traceability through unique serial number for each filter
- Individual certificate of quality for each device
- Sterilizable by EO gas or autoclaving
Sterile Filtration of:
- Cell culture media
- Cell culture media containing serum
- Media additives
- pH adjusters
- Final product concentrates
Bioburden Reduction/ Particulate Removal:
- Buffers
- Centrifuge supernatants
- Clarified cell lysates
Construction | |||||
Final Filter Membrane | 0.2µm Hydrophilic PES | ||||
Prefilter Membrane | 0.5µm Hydrophilic PES | ||||
Support Layers | Polyester | ||||
Body and Core | Polypropylene | ||||
Size | |||||
Size |
|
||||
Effective Filtration Area (Nominal) |
|
||||
Dimension (End to End) – ½” Hose Barb I/O |
|
||||
Dimension (End to End) – 1½” Sanitary Flange Inlet ½” Single Step Hose Barb Outlet |
|
||||
Dimensions (End to End) – ¾” Sanitary Flange I/O |
|
||||
Dimension (End to End) – 1½” Sanitary Flange I/O |
|
||||
Dimension (End to End) – ½” Single Step Hose Barb I/O |
|
||||
Operational Radius (with Vent/ Drain) |
|
||||
Vent and Drain |
|
||||
Integrity Testing / Retention | |||||
Bubble Point | > 50psi (3.52Kg/cm²) with Water | ||||
Microbial Retention | LRV >7 for Brevundimonas diminuta (ATCC 19146) per cm² | ||||
Operational | |||||
Max. Operating Temperature | 80 °C @ < 2 Kg/cm² (30 psi) | ||||
Max. Differential Pressure | 4 Kg/cm² (60 psi) @ 30 °C | ||||
pH Compatibility | Compatible with pH range of 1-10 | ||||
Sterilization By Gas | Sterilizable by Ethylene Oxide | ||||
Sterilization By Autoclave | Autoclavable at 125°C for 30 minutes, 3 cycles and it cannot be in-line steam sterilized | ||||
Shelf Life | 3 years after EO sterilization | ||||
Assurance | |||||
Toxicity | Passes Bioreactivity test, In Vivo, as per USP <88> for Class VI plastics | ||||
Cytotoxicity | Passes Biological Reactivity Tests, In Vitro, USP <87> for cytotoxicity | ||||
Bacterial Endotoxin | Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test as per USP <85> | ||||
Bioburden | Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018 | ||||
Non Fiber Releasing | Passes test as per USP and comply with USFDA 21 CFR Part 210.3(b)(6) for fiber release | ||||
Indirect Food Additive | All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520 | ||||
Extractables with WFI | Passes NVR test as per USP <661> | ||||
Good Manufacturing Practice | These products are manufactured in a facility which adheres to Good Manufacturing Practices | ||||
Oxidizable Substances | Within limits as specified in USP <1231> | ||||
Particle Shedding | Passes USP test for particulates in injectables | ||||
TOC/Conductivity at 25 °C | Meets the WFI requirements of USP <643> for Total Organic Carbon and USP <645> for Water Conductivity after a specified volume of purified water flush | ||||
Quality Management System | ISO-9001 Certified | ||||
USFDA | DMF No. 015554 |
|
|
|
|
|
|
|
|
*1” Capsule Filters are not available with ½” Single Step Hose Barb and ½” MNPT
**Male luer slip is available only in 1” capsule filter as outlet
***3/16″ Hose Barb end connection is available in:
- 1″ and 2″ capsule filters as inlet and outlet
- 5″ capsule filters as outlet only
****Bell and bell with cover is available with:
- ½” Hose Barb outlet connections in 1″, 2″, 5″ and 8″ Capsule filters
- ¼” SHB outlet connection in 1″ capsule filters only
Example :
DKX7 | 53 | 01 | DD | X | X | 1 | 01 |
Example for Non Sterile: DKX75301DDXX101 Example for EO Sterile: DKX75301DDXX201