AseptiSure KR Mini 2.5", 5"
mdi AseptiSure KR mini cartridge filters incorporate a low protein binding PES membrane with polypropylene drainage layers to ensure pH compatibility from 1-14 making these ideal for alkaline fluid streams.
Consistent and Reliable Quality: | AseptiSure cartridge filters are produced with ISO 9001-2008 certified quality management systems. |
Regulatory Compliance: | Meet all pharmacopeial and compendia requirements and are registered with USFDA DMF #015554 |
Low Protein Binding: | Results in increased overall product yield with biological streams. |
High Throughputs: | Translates to lower filtration costs, less number of filter changes and overall economy of operations. |
Low Extractables: | mean less addition to impurity profile of the biological product from the filters. |
- For sterile filtration of alkaline fluid streams such as pH adjusters for microbial fermentation processes.
Construction | |||
Membrane | Hydrophilic PES | ||
Pore size |
|
||
Support Layers | Polypropylene | ||
Body and Core | Polypropylene | ||
Integrity Testing / Retention | |||
Bubble Point |
|
||
Microbial Retention |
|
||
Size | |||
Size |
|
||
Effective Filtration Area (Nominal) |
|
||
Operational | |||
Max. Operating Temperature | 80 °C @ < 2 Kg/cm² (30 psi) | ||
Max. Differential Pressure | < 3.5 Kg/cm² (50 psi) @ 25 °C | ||
Reverse Pressure | < 0.7 Kg/cm² (10 psi) @ 25 °C | ||
Sterilization | Autoclavable/In-line steam sterilizable at 121 ° C for 30 minutes, 25 cycles | ||
Assurance | |||
Toxicity | Passes Bioreactivity test, In Vivo, as per USP <88> for Class VI plastics | ||
Cytotoxicity | Passes Biological Reactivity Tests, In Vitro, USP <87> for cytotoxicity | ||
Bacterial Endotoxin | Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test | ||
Bioburden | Bioburden level is < 1000 cfu/filter device as per ANSI/AAMI/ISO 11737-1 : 1995 | ||
Non Fiber Releasing | Passes test as per USP and comply with USFDA 21 CFR Part 210.3(b)(6) for fiber release | ||
Indirect Food Additive | All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520 | ||
Extractables with WFI | Passes test as per USP | ||
Good Manufacturing Practice | These products are manufactured in a facility which adheres to Good Manufacturing Practices. | ||
Oxidizable Substances | Within limits as specified in USP | ||
Particle Shedding | Passes USP test for particulates in injectables. | ||
TOC/Conductivity at 25 °C | Meets the WFI requirements of USP <643> for Total Organic Carbon and USP <645> for Water Conductivity after a specified volume of purified water flush | ||
Quality Management System | ISO-9001 Certified | ||
USFDA | DMF No. 015554 | ||
pH Compatibility | Compatible with pH range of 1 - 14 |
|
|
|
|
|
|
|