UA-44035381-1
  • AseptiWave™ Bioreactors

AseptiWave™ Bioreactors

mdi AseptiWave™ single use bioreactors are designed for efficient culture of different type of cells including Mammalian cells, Plant cells, Insect cells, Microbial cells, Stem cells etc.

These are available gamma sterilized, in multiple sizes ranging from 1 liters for clone selection and media optimization labs, up to 200 liters, for process development as well as GMP production of biopharmaceuticals.

  • Cell Culture
  • Expansion of anchorage dependent cells such as epidermal and connective tissue cells
  • Small scale expansion of stem cells
  • Inoculum propagation
  • Development and manufacture of:
    • Therapeutic protein
    • Monoclonal Antibodies (mAbs)
  • Expansion of CAR T cells for cell therapy
Construction
Materials of Construction

AseptiWave Bioreactor FilmMultilayered Film FBG-1
BioVent Gas FilterHydrophobic Filter Media
Specifications
Sizes Available
SizeMinimum Culture Volume* Maximum Culture Volume 
1L150ml500ml
2L300ml1L
5L500ml2.5L
10L1L5L
20L2L10L
22L2L10L
50L5L25L
100L15L50L
200L30L100L

*The minimum culture volume specified is for AseptiWave™Bioreactors with pH and DO sensors. It might be possible to work with lower culture volumes forAseptiWave™Bioreactors without sensors.However, it is recommended to have culture volumes above the minimum specified volumes for application that require high agitation

Operational
Sterilization AseptiWave bioreactors are Gamma Sterilizable upto 50 kGy.
Assurance
Bioburden Bioburden level is < 1000 cfu/device as per ISO 11737-1:2018.
Fiber Release Passes test as per USP and comply with USFDA Title 21 CFR Part 210.3(b)(6) for fiber release.
Particle Release Complies with USP <788> test for particulate matter in injections.
Endotoxin Testing Aqueous extracts exhibit <0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test as per USP <85>.
Extractables The Extractable profile is available as per BioPhorum Best Practices Guide for Extractable Testing of Polyemric Single Use Components used in Biopharmaceutical Manufacturing.
Sterility The gamma sterilization process has been validated as per ISO 11137 to ensure a sterility assurance level (SAL) of 10-6.
Biosafety

Passes Biological Reactivity test, In-Vivo, as per USP<88> for Class VI plastics.

Passes the Biological Reactivity Tests, In Vitro for Cytotoxicity as described in USP<87>.

AseptiWave™ bioreactors are available with and without pH and DO sensors.

AseptiWave OS bioreactors integrate pre-calibrated optochemical pH and DO sensors, for monitoring pH and dissolved oxygen in the culture, allowing efficient cell cultivation.

The calibration data for the optical sensors is provided along with the bioreactors.

TypepH and DO Optical Sensor
AseptiWave™No
AseptiWave™ OSYes

Datasheet Download