Edge Hydrophobic CN Membrane Disc Filters Type- EHCN
mdi Edge Hydrophobic Membrane Disc Filters are used for sterility testing of antibiotics and drugs containing bacteriostats. The 6mm hydrophobic edge does not allow the drug to seep under the rim of the filter holder during filtration. This ensures complete removal of the drug during flushing so that growth of any microorganisms which have been retained on the membrane is not inhibited due to the residual drug, improving the sensitivity and reliability of the test.
Cost reduction is possible by reducing or eliminating antibiotic breaking enzymes.
mdi filters are produced in a facility with ISO-9001:2008 certified quality management system.
- Sterility testing of antibiotics and drugs containing bacteriostats
- Product Microbiology of antibiotics and drugs containing bacteriostats
Construction | |
Membrane | Cellulose Nitrate membrane with 6mm Hydrophobic Rim |
Pore size | 0.45μm |
size | 47mm |
Operational | |
Bubble Point | > 32psi (2.25Kg/cm²) with water |
Sterilization By Gas | Pre-sterilized with EO |
Water Flow Rate | > 45ml/min/cm² @ 0.70 Kg/cm² @ 27 °C |
Retention Efficiency | LRV > 7 for Sr. marcescens |
Assurance | |
Non Fiber Releasing | Passes test as per USP and comply with USFDA 21 CFR Part 211.72 for fiber release |
Oxidizable Substances | Within limits as specified in USP |
Quality Management System | ISO-9001 Certified |
|
|
|
|
|
|
|
Example :