DGKX5101AAXX101
DGKX5104AAXX101
DGKX5104BAXX101
DGKX5104DDXX101
DGKX5104EEXX101
DGKX5201AAXX101
DGKX5201DDXX101
DGKX5201EEXX101
DGKX5204AAXX101
DGKX5204DDXX101
DGKX5204EQXX101
DGKX5204SSXX101
DGKX5204SSXX201
DGKX5236DDXX101
DGKX5301DDXX101
DGKX5301EEXX101
DGKX5301SSXX201
DGKX5304DDXX101
DGKX5304DDXX301
DGKX5304EEXX101
DGKX5304EEXX201
DGKX5304EQXX101
DGKX5304SSXX101
DGKX5304SSXX201
DGKX5704AAXX101
DGKX5704DDXX101
DGKX5704EQXX101
DGKX5704SSXX101capsule filters, filters
- High Flow Rates
- High Throughput
- Very High Retention
- Low Protein Binding
- Compact Design
- Precipitate removal post viral inactivation
- Pre-filtration of serum solutions
- Clarification of cell harvest supernatants
- Polishing of turbid solutions
Construction |
Membrane |
Hydrophilic PES |
Pore size |
0.1µm, 0.2µm, 0.5µm |
Prefilter Membrane |
Microglassfiber |
Support Layers |
Polyester |
Body and Core |
Polypropylene |
Size |
Size |
|
Effective Filtration Area (Nominal) |
150cm² | 500cm² | 1000cm² | 1500cm² |
|
Dimension (End to End) - 1½" Sanitary Flange Inlet ½" Single Step Hose Barb Outlet |
|
Dimension (End to End) - ¾" Sanitary Flange I/O |
85 mm |
104 mm |
155 mm |
206 mm |
|
Dimension (End to End) - 1½" Sanitary Flange I/O |
92 mm |
112 mm |
164 mm |
216 mm |
|
Dimension (End to End) - ½" Hose Barb I/O |
90 mm |
112 mm |
162 mm |
214 mm |
|
Dimension (End to End) - ½" Single Step Hose Barb I/O |
|
Operational Radius (with Vent/ Drain) |
|
Vent and Drain |
¼" Hose Barb with Silicone "O" rings for 2", 5", and 8" capsule filters |
Operational |
Max. Operating Temperature |
80 °C @ < 30 psi (2 Kg/cm²) |
Max. Differential Pressure |
< 60 psi (4 Kg/cm²) @ 30° C |
Sterilization By Gas |
Sterilizable by Ethylene Oxide |
Sterilization By Autoclave |
Autoclavable at 125°C for 30minute, 25 cycle and it cannot be In-line steam sterilized |
Shelf Life |
3 years after EO sterilization |
Assurance |
Toxicity |
Passes Bioreactivity test, In Vivo, as per USP for Class VI plastics |
Bacterial Endotoxin |
Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test |
Bioburden |
Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018 |
Non Fiber Releasing |
Passes test as per USP and comply with USFDA 21 CFR Part 210.3 (b)(6) for fiber release |
Particle Release |
The filtrate complies with USP <788> test for particulate matter in injections |
Indirect Food Additive |
All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520 |
Extractables with WFI |
Passes test as per USP |
Good Manufacturing Practice |
These products are manufactured in a facility which adheres to Good Manufacturing Practices. |
Oxidizable Substances |
Within limits as specified in USP |
Quality Management System |
ISO-9001 Certified |
USFDA |
DMF No. 015554 |
| Size | Size | Code | 1" | 51 | 2" | 52 | 5" | 53 | 8" | 57 | | Pore Size | Pore Size | Code | 0.1µm | 36 | 0.2µm | 01 | 0.5µm | 04 | | I/O Connection | Connection | Code | ¼” SHB | A | ¼" MNPT* | B | ¼” BSP (19 TPI) | M | ¼” BSP (19 TPI) with O-ring | P | ¼” BSP | F | ½" MNPT | C | ½” Hose Barb | D | 1½" Sanitary Flange | E | ¾" Sanitary Flange | S | Quick Connector | J | Single Step ½" Hose Barb* | Q | Female Luer Lock | U | Male Luer Slip** | W | 3/8" Hose Barb* | I | 3/16" Hose Barb*** | N | | | | Sterility | | Code | Non Sterile | 1 | EO Sterile | 2 | | Pack Size | Pack Size | Code | 1 | 01 | |
*1" Capsule filters are not available with ½" Single Step Hose Barb Connections, ½" MNPT and 3/8" Hose Barb
**Male luer slip is available only in 1” capsule filter as outlet
***3/16" Hose Barb end connection is available in:
- 1" and 2" capsule filters as inlet and outlet
- 5" capsule filters as outlet only
Example :
Example for Non Sterile: DGKX5704DDXX101 Example for EO Sterile: DGKX5704DDXX201