cartridge filters, filters
Consistent and Reliable Quality:
| ClariSure® cartridge filters are produced with ISO 9001-2008 certified quality management systems.
|
Regulatory Compliance:
| Meet all pharmacopeial and compendia requirements and are registered with USFDA DMF #015554
|
Total Traceability
| Unique identification number is laser etched on each other.
|
- Precipitate removal post viral inactivation
- Pre-filtration of cell culture media
- Pre-filtration of serum and other viscous biologicals
- Pre-filtration of serum solutions
- Clarification of cell harvest supernatant
- Pre-filtration of high value difficult to filter drug solutions
- Polishing of turbid solutions
Construction |
Pore size |
0.1μm, 0.2μm, 0.5μm |
Prefilter Membrane |
Microglassfiber |
Support Layers |
Polyester |
Body and Core |
Polypropylene |
Size |
Size |
|
Effective Filtration Area |
|
Materials of Construction |
Filter Membrane |
Hydrophilic PES |
Operational |
Max. Operating Temperature |
80 °C @ < 30 psi (2 Kg/cm²) |
Max. Differential Pressure |
50 psi (3.5 Kg/cm²) @ 25 °C |
Sterilization |
Autoclavable/In-line steam sterilizable at 121 °C for 30minutes, 25 cycles |
Assurance |
Toxicity |
Passes Bioreactivity test, In Vivo, as per USP for Class VI plastics |
Cytotoxicity |
Passes Biological Reactivity Tests, In Vitro, USP <87> for cytotoxicity |
Non Fiber Releasing |
Passes test as per USP and comply with USFDA 21 CFR Part 210.3(b)(6) for fiber release |
Indirect Food Additive |
All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520 |
Extractables with WFI |
Passes test as per USP |
Good Manufacturing Practice |
These products are manufactured in a facility which adheres to Good Manufacturing Practices. |
Oxidizable Substances |
Within limits as specified in USP |
Particle Shedding |
Passes USP test for particulates in injectables |
Quality Management System |
ISO-9001 Certified |
USFDA |
DMF No. 015554 |
Type | ClariSure® GK Mini
| CGKX | | Size | Size | Code | 2.5" | 50 | 5" | 53 | | Pore Size | Pore Size | Code | 0.1µm | 36 | 0.2µm | 01 | 0.5µm | 04 | | Adapter | | Code | 4463 | E0 | 4463B | H0 | 4440 | U0 | Seal-K
| G0* | Seal-O
| F0** | Seal-M
| J0 | | Elastomer | | Code | Silicone | SS | | Sterility
| | Code | Non Sterile | 1 | | Pack Size | Pack Size | Code | 1 | 01 | |
*G0 adapter code is not available with any elastomer. Please mention XX in place of elastomer code while ordering
**Adapter code F0 is available only in 5” cartridge filters
Example:
Example for Non Sterile: CGKX5004E0SS101