ClariCap® GS 5", 10", 20", 30"
mdi ClariCap® GS Microglassfiber Capsule Filters are multilayered, high throughput filters, specially designed for turbid and difficult to filter solutions. The microglassfiber medium is designed to retain colloidal particles and for removal of deformable and nondeformable particles and microorganisms from liquids.
The polypropylene layer downstream of microglassfiber layers prevents media migration. The high dirt holding capacity, biochemical inertness, adsorption and high wet strength of the filtration medium makes it suitable for clarification and prefiltration of wide range of aqueous, non-aqueous and biologicals solutions.
- Very high particulate retention efficiency
- High throughput
- High heat resistance
- Wide chemical compatibility
- No media migrating
- Biologically inert
- Easy installation
- Pre-filtration of high value difficult to filter drug solutions
- Precipitate removal in protein processing and plasma fractions
- Removal of un-dissolved buffer salts and cell culture media
- Prefiltration of serum and other viscous biologicals
- Polishing of turbid solutions
Construction | |||||
Pore size | 0.7µm, 1µm, 1.5µm, 2µm | ||||
Filter Media | Multilayered Microglassfiber | ||||
Downstream Layer | Polypropylene | ||||
Body and Core | Polypropylene | ||||
Size | |||||
Effective Filtration Area (Nominal) |
|
||||
Length |
|
||||
Dimension (End to End) - ¾" Sanitary Flange I/O |
|
||||
Dimension (End to End) - 1½" Sanitary Flange I/O |
|
||||
Dimension (End to End) - ½" Single Step Hose Barb |
|
||||
Dimensions (End to End) Inline Capsule Filters - 1½" Sanitary Flange Inlet ½" Single Step Hose Barb Outlet |
|
||||
Dimension (End to End) - 1" Hose Barb I/O |
|
||||
Operational Radius (with Vent/ Drain) |
|
||||
Dimension (End to End) - 3/8" Hose Barb I/O |
|
||||
Vent and Drain | ¼" Hose Barb with Silicone "O" ring | ||||
Operational | |||||
Max. Operating Temperature | 80 °C @ < 30 psi (2 Kg/cm²) | ||||
Max. Differential Pressure | < 60 psi (4 Kg/cm²) @ 30 °C | ||||
Sterilization | Sterilizable by Ethylene Oxide | ||||
Shelf Life | 3 years after EO Sterilization | ||||
Assurance | |||||
Toxicity | Passes Bioreactivity test, In Vivo, as per USP for Class VI plastics | ||||
Bacterial Endotoxin | Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test | ||||
Bioburden | Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018 | ||||
Non Fiber Releasing | Passes test as per USP and comply with USFDA 21 CFR Part 210.3(b)(6) for fiber release | ||||
Particle Release | The filtrate complies with USP <788> test for particulate matter in injections | ||||
Indirect Food Additive | All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520 | ||||
Extractables with WFI | Passes test as per USP | ||||
Good Manufacturing Practice | These products are manufactured in a facility which adheres to Good Manufacturing Practices. | ||||
Oxidizable Substances | Within limits as specified in USP | ||||
Quality Management System | ISO-9001 Certified | ||||
USFDA | DMF No. 015554 |
|
|
|
|
|
|
|
|
* T-line Capsule filter are available with 1½" Sanitary Flange I/O Connection only
* T-line is not available in 5" capsule filter
**3/4" Sanitary Flange end connection is available only in 5" and 10" capsule filters
***1" Hose Barb is not available in 5" capsule filters
Example :
LGSX | 54 | 14 | X | X | 1 | 01 |