UA-44035381-1
  • AseptiCap<sup>®</sup> NSZ 1", 2", 5", 8"

AseptiCap® NSZ 1", 2", 5", 8"

mdi AseptiCap NSZ positively charged Nylon 66 membrane capsule filters are absolute retention, serial filtration devices for sterilization of liquids. The upstream layer with larger pore size protects the downstream final layer for enhanced throughputs.

The positive charge of the membrane offers enhanced capability to retain negatively charged contaminants such as endotoxins and colloids even smaller than the membrane pore size rating.

These filters are biologically inert, autoclavable, heat resistant, exhibiting wide chemical compatibility, and are suitable for a large number of filtration and sterilization applications including ophthalmic, and injectable solutions.

  • Positively charged to retain contaminants smaller than pore size rating
  • High flow rates and throughputs
  • Minimal extractables
  • High heat resistance
  • Wide chemical compatibility
  • Biologically inert
  • Hydrophilic
  • Filtration of pharmaceutical solutions
  • Sterilizing filtration of wide variety of compatible organic solvents
  • Sterilization of laboratory disinfectants
  • Filtration of buffers and other non-aqueous solutions
Construction
Membrane Positively Charged Nylon 66
Final Filter Pore Size 0.2µm
Prefilter Pore Size
0.45µm0.8µm
Support Layers Polyester
Body and Core Polypropylene
Size
Size
1"2" 5"8"
Effective Filtration Area (Nominal)
200cm²700cm²1400cm²2100cm²
Dimension (End to End) - 1½" Sanitary Flange I/O
92 mm112 mm164 mm216 mm
Dimension (End to End) - ½" Single Step Hose Barb I/O
--115 mm162 mm218 mm
Integrity Testing / Retention
Microbial Retention LRV >7 for Brevundimonas diminuta (ATCC 19146) per cm²
Bubble Point (with 50% IPA) > 17psi (1.19Kg/cm²)
Operational
Max. Operating Temperature 80 °C @ < 30 psi (2 Kg/cm²)
Max. Differential Pressure < 60 psi (4 Kg/cm²) @ 30 °C
Sterilization By Gas Sterilizable by Ethylene Oxide
Sterilization By Autoclave Autoclavable at 125 °C for 30 minutes, 1 cycles and it cannot be inline steam sterilized.
Assurance
Toxicity Passes Bioreactivity test, In Vivo, as per USP <88> for Class VI plastics
Bacterial Endotoxin Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test
Bioburden Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018
Non Fiber Releasing Passes test as per USP and comply with USFDA 21 CFR Part 210.3(b)(6) for fiber release
Particle Release The filtrate complies with USP <788> test for particulate matter in injections
Indirect Food Additive All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520
Extractables with WFI Passes test as per USP
Good Manufacturing Practice These products are manufactured in a facility which adheres to Good Manufacturing Practices.
Oxidizable Substances Within limits as specified in USP
TOC/Conductivity at 25 °C Meets the WFI requirements of USP <643> for Total Organic Carbon and USP <645> for Water Conductivity after a specified volume of purified water flush
Quality Management System ISO-9001 Certified
USFDA DMF No. 015554

Type
AseptiCap NSZ (0.45 μm Upstream) DNZX
AseptiCap NSZ (0.8 μm Upstream) DNZ5
Size
Size Code
1"** 51
2" 52
5" 53
8" 57
Pore Size
Pore Size Code
0.2µm 01
I/O Connection
Connection Code
¼” SHB A
¼” MNPT B
¼” BSP (19 TPI) M
¼” BSP (19 TPI) with O-ring P
¼” BSP F
½” MNPT**C
½”Hose Barb D
½" Sanitary Flange E
¾" Sanitary Flange S
Quick Connector J
Single Step ½" Hose Barb*
Q
Female Luer Lock U
Male Luer Slip** W
3/8" Hose Barb* I
3/16" Hose Barb*** N
X
Bell
Code
Yes**** B
Bell with cover**** C
No Bell X
Sterility
Code
Non Sterile 1
EO Sterile 2
Pack Size
Pack Size Code
1 01

*1” Capsule Filters are not available with ½” Single step Hose Barb, ½” MNPT and 3/8" Hose Barb

**Male luer slip is available only in 1” capsule filter as outlet

***3/16" Hose Barb end connection is available in:

  • 1" and 2" capsule filters as inlet and outlet
  • 5" capsule filters as outlet only

****Bell or bell with cover is available with:

  • ½" Hose Barb Connections in 1", 2", 5" and 8" capsule filters
  • ¼" SHB outlet connection in 1" capsule filters only

Example :

DNZX 52 01 DD X X 1 01

Example for Non Sterile: DNZX5201DDXX101                                                            Example for EO Sterile: DNZX5201DDXX201>

AseptiCap NSZ Small flow rates

Datasheet Download
Certificate of Quality Download

Write a review

Note: HTML is not translated!