CWH15036 |
CWH15336 |
CWHX5036 |
CWHX5336 |
Cartridge filters, filters
- Absolute retention
- 100% integrity tested
- Low protein binding
- Low extractables
- Cell culture media
- Growth Regulators
- Small Volume Parenterals
Construction |
Membrane |
Hydrophilic PVDF |
Final Filter Pore Size |
0.1µm |
Prefilter Pore Size |
0.2µm or 0.45 µm |
Support Layers |
Polyester |
Plastic parts |
Polypropylene |
Body and Core |
Polypropylene |
Integrity Testing / Retention |
Bubble Point |
> 31psi (2.18Kg/cm²) with 50%
IPA/Water Solution |
Microbial Retention |
LRV >7 for A. laidlawii
(ATCC 23206) per cm² |
Size |
Size |
|
Effective Filtration Area (Nominal) |
|
Operational |
Max. Operating Temperature |
80 °C @ < 2 Kg/cm² (30 psi) |
Max. Differential Pressure |
3.5 Kg/cm² (50 psi) @ 25 °C |
Reverse Pressure |
< 0.7 Kg/cm² (10 psi) @ 25 °C |
Sterilization |
Autoclavable/ Inline steam sterilizable at 135°C for 3 cycles of 30 minutes each |
Assurance |
Toxicity |
Passes Bioreactivity test, In Vivo, as per USP <88> for Class VI plastics |
Cytotoxicity |
Passes Biological Reactivity Tests, In Vitro, USP <87> for cytotoxicity |
Bacterial Endotoxin |
Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test |
Bioburden |
Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018 |
Non Fiber Releasing |
Passes test as per USP and comply with USFDA 21 CFR Part 210.3(b)(6) for fiber release |
Indirect Food Additive |
All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520 |
Extractables with WFI |
Passes test as per USP |
Good Manufacturing Practice |
These products are manufactured in a facility which adheres to Good Manufacturing Practices. |
Oxidizable Substances |
Within limits as specified in USP |
Particle Shedding |
Passes USP test for particulates in injectables. |
TOC/Conductivity at 25 °C |
Meets the WFI requirements of USP <643> for Total Organic Carbon and USP <645> for Water Conductivity after a specified volume of purified water flush |
Quality Management System |
ISO-9001 Certified |
USFDA |
DMF No. 015554 |
Type | AseptiSure WS (0.2µm upstream) | CWH1 | AseptiSure WS (0.45µm upstream) | CWHX | | Size | Size | Code | 2.5" | 50 | 5" | 53 | | Pore Size | Pore Size
| Code | 0.1µm | 36 | | Adapter | | Code | 4463 | E0 | 4463B | H0 | 4440 | U0 | Seal-K
| G0* | Seal-O
| F0** | Seal-M
| J0 | | Elastomer | | Code | Silicone | SS | | Sterility | | Code | Non Sterile | 1 | | Pack Size | Pack Size | Code | 1 | 01 | |
*G0 adapter code is not available with any elastomer. Please mention XX in place of elastomer code while ordering
**Adapter code F0 is available only in 5” cartridge filters