CPK15336A1SS101 |
CPKX5336A0SS101 |
CPKX5336H0SS101 |
CPKX5436A0SS101 |
CPKX5436B0SR101 |
CPKX5536A0SS101 |
CPKX5536B0SR101 |
Cartridge filters, filters
Consistent and Reliable Quality:
| AseptiSure® cartridge filters are produced with ISO 9001-2008 certified quality management systems.
|
Regulatory Compliance:
| Meet all pharmacopeial and compendia requirements and are registered with USFDA DMF #015554
|
Low Protein Binding:
| Results in increased overall product yield and higher throughputs with biological streams.
|
High Throughputs:
| Translates to lower filtration costs, less number of filter changes and overall economy of operations.
|
Low Extractables:
| Means less addition to impurity profile of the biological product from the filters.
|
- Sterile Filtration of Culture media for mammalian cell culture
Construction |
Membrane |
Hydrophilic PES |
Final Filter Pore Size |
0.1µm |
Prefilter Pore Size |
0.2 µm or 0.45 µm |
Support Layers |
Polyester |
Body and Core |
Polypropylene |
Size |
Size |
|
Effective Filtration Area (Nominal) |
3000cm² |
6000cm² |
12000cm² |
18000cm² |
|
Integrity Testing / Retention |
Bubble Point |
> 26 psi (1.82 Kg/cm²) with 50% IPA > 65 psi (4.56 Kg/cm²) with Water |
Microbial Retention |
LRV >7 for Acholeplasma laidlawii (ATCC 23206) per cm² |
Air Diffusion Flow (10") |
< 29ml/min @ 50 psi (3.51 Kg/cm²) with Water |
Operational |
Max. Operating Temperature |
80 °C @ < 2 Kg/cm² (30 psi) |
Max. Differential Pressure |
3.5 Kg/cm² (50 psi) @ 25 °C |
Reverse Pressure |
< 0.7 Kg/cm² (10 psi) @ 25 °C |
Typical Water Flow Rates (10" Cartridge filters) |
22 lpm @ 0.70 Kg/cm² @ 27 °C |
Sterilization |
Autoclavable/In-line steam sterilizable at 121 °C for 30 minutes, 25 cycles |
Assurance |
Toxicity |
Passes Bioreactivity test, In Vivo, as per USP <88> for Class VI plastics |
Cytotoxicity |
Passes Biological Reactivity Tests, In Vitro, USP <87> for cytotoxicity |
Bacterial Endotoxin |
Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test |
Bioburden |
Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018 |
Non Fiber Releasing |
Passes test as per USP and comply with USFDA 21 CFR Part 211.72 for fiber release |
Indirect Food Additive |
All Polypropylene components meet the FDA Indirect Food Additive requirements cited in 21 CFR 177.1520 |
Extractables with WFI |
Passes test as per USP |
Good Manufacturing Practice |
These products are manufactured in a facility which adheres to Good Manufacturing Practices. |
Oxidizable Substances |
Within limits as specified in USP |
Particle Shedding |
Passes USP test for particulates in injectables. |
TOC/Conductivity at 25 °C |
Meets the WFI requirements of USP <643> for Total Organic Carbon and USP <645> for Water Conductivity after a specified volume of purified water flush |
Quality Management System |
ISO-9001 Certified |
USFDA |
DMF No. 015554 |
pH Compatibility |
Compatible with pH range of 1 - 10 |
Type | AseptiSure® KS (0.2 μm Upstream)
| CPK1 | AseptiSure® KS (0.45 μm Upstream)
| CPKX | | Size | Size | Code | 5"** | 53 | 10" | 54 | 20" | 55 | 30" | 56 | | Pore Size | Pore Size
| Code | 0.1µm | 36 | | Adapter | | Code | 7P | A0 | 7P without fin | A1 | 28 with fin | C0 | 'O' | D0 | | Elastomer | | Code | Silicone | SS | Viton | SV | EPDM | SE | FEP Encapsulated Viton | FV* | | Sterility | | Code | Non Sterile | 1 | | Pack Size | Pack Size | Code | 1 | 01 | |
* FV is available in Adapter code A0(7P) and A1(7P without fin) only
** Size 5" is available in Adapter Code A0 (7P) and A1 (7P without fin) only
Example :
Example for Non Sterile: CPKX5336E0SS101