MDI AseptiCap® KS-γ PES membrane capsule filters are validated for mycoplasma removal and are used for sterile media filtration in mammalian cell culture.

These are gamma sterilizable and are available in a wide range of sizes and end connections.

  • Absolute retention
  • 100% integrity tested
  • Low protein binding
  • Very low hold up volume in filters
  • High flow rates
  • Serial construction with prefilter for higher throughput with fouling streams
  • Bioburden maintained below 1000 cfu/device
  • Endotoxin level certified to be <0.25 EU/ml
  • Widest range of end connections
  • Products available for total scalability from a few ml to thousands of liters
  • Total traceability through unique serial number for each filter
  • Individual certificate of quality for each device
  • Sterilizable by EO gas or autoclaving

 

Sterile Filtration of:

  • Cell culture media
  • Cell culture media containing serum
  • Media additives
  • pH adjusters
  • Final product concentrates

Bioburden Reduction/ Particulate Removal:

  • Buffers
  • Centrifuge supernatants
  • Clarified cell lysates

Construction
Membrane 0.1 μm Hydrophilic PES
Upstream Membrane 0.2 µm or 0.45 µm Hydrophilic PES
Support Layers Polyester
Plastic parts Gamma Stable Polypropylene
Size
Size
1″ 2″ 5″ 8″
Effective Filtration Area (Nominal)
250cm² 500cm² 1000cm² 2000cm²
Dimensions (End to End) – 1½” Sanitary Flange I/O
92 mm 112 mm 164 mm 216 mm
Dimension (End to End) – ½” Hose Barb I/O
90 mm 112 mm 162 mm 214 mm
Dimension (End to End) – 1½” Sanitary Flange Inlet ½” Single Step Hose Barb Outlet
112 mm 165 mm 216 mm
Dimensions (End to End) – ¾” Sanitary Flange I/O
85 mm 104 mm 155 mm 206 mm
Dimension (End to End) – ½” Single Step Hose Barb I/O
115 mm 162 mm 218 mm
Clean water Flow Rate @ 10 psi with ½” Hose Barb Connection
1.3 lpm 2.5 lpm 4.8 lpm 6.5 lpm
Operational Radius (with Vent/ Drain)
40 mm 65 mm 65 mm 65 mm
Vent and Drain 1/4” Hose Barb with Silicone “O” ring
Integrity Testing / Retention
Bubble Point > 26 psi (1.82 Kg/cm²) with 50% IPA

> 65 psi (4.56 Kg/cm²) with Water

Bacterial Retention LRV > 7 for Acholeplasma laidlawii ATCC 23206 per cm² of filter area

LRV> 7 for Brevudimonas diminuta ATCC 19146 per cm² of filter area as per ASTM F 838

Operational
Max. Operating Temperature 80 °C @ < 30 psi (2 Kg/cm²)
Max. Differential Pressure 60 psi (4 Kg/cm²) @ 30 °C
Sterilization By Irradiation Gamma Irradiatiable up to 50 kGy. These filters should not be autoclaved or in-line steam sterilized.
Shelf Life 2 years after gamma sterilization
Assurance
Toxicity Passes Bioreactivity test, In Vivo, as per USP <88> for Class VI plastics
Cytotoxicity Passes Biological Reactivity Tests, In Vitro, USP <87> for cytotoxicity
Bacterial Endotoxin Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test as per USP <85>
Bioburden Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018
Non Fiber Releasing Passes test as per USP and comply with USFDA 21 CFR Part 210.3(b)(6) for fiber release
TOC and Conductivity Meets the WFI requirements of USP for TOC <643> and Conductivity <645> after a 3 liter flush
Indirect Food Additive Comply with USFDA 21 CFR Part 177.1520
Extractables with WFI Passes NVR test as per USP <661>
Oxidizable Substances Within limits as specified in USP <1231>
Particle Shedding Passes USP test for particulates in injectables
Quality Management System ISO-9001 Certified
USFDA DMF No. 015554
pH Compatibility Compatible with pH range of 1 – 10

Type
AseptiCap® KS-γ
(0.45µm Upstream)
DKSX
AseptiCap® KS-γ
(0.2µm Upstream)
DKS1
Size
Code
1″ 51
2″ 52
5″ 53
8″ 57
Pore Size
Pore Size Code
0.1µm 36
I/O Connection
Connection Code
¼” SHB A
½” HB D
1½” Sanitary Flange E
¾” Sanitary Flange S
Quick Connector J
Single Step ½” HB* Q
Female Luer Lock U
Male Luer Slip** W
3/8″ HB* I
3/16″ HB*** N
¼” Single Step HB R
Radiation Sterilizable
Code
Yes R
Noa X
Bellb
Code
Yes B
No Bell X
Bell with cover C
Sterility
Code
Non Sterile 1
Gamma Sterile 3
Pack Size
Qty Code
1 01

*1” Capsule Filters are not available with ½” Single step Hose Barb and ½” MNPT

** Male luer slip is available only in 1” capsule filter as outlet

*** 3/16″ Hose Barb end connection is available in:

  • 1″ and 2″ capsule filters as inlet and outlet
  • 5″ capsule filters as outlet only

a: Gamma sterilized filters cannot be gamma irradiated again

b: Bell and bell with cover is available with:

  • ½” HB outlet connections in 1″, 2″, 5″ and 8″ capsule filters
  • ¼” SHB outlet connection in 1″ capsule filters only

Example:

DKSX 57 36 DD R X 1 01

Example for Non Sterile: DKSX5136EERX101