AseptiVent® VF-γ Inline
MDI AseptiVent® VF-γ, gamma sterilizable PVDF membrane vent filters are validated for microbial retention with liquid bacterial challenge test as per ASTM F838 to provide a high degree of sterility assurance for critical applications such as small bioreactors, sterile tank venting, bottle venting etc.
- Absolute retention
- 100% integrity tested
- High hydrophobicity
- High air flow rates
- Low Bioburden, <1000 cfu/device
- Endotoxin level certified to be <0.25 EU/ml
- Widest range of end connections
- Products available for total scalability from seed reactors process scale bioreactors/fermentors
- Total traceability (unique serial number for each filter)
- Individual certificate of quality for each device
- Sterilizable by Gamma irradiation
- Sterile air sparging
- Sterile venting
- Fermentor exhaust
Construction | ||||
Membrane | Hydrophobic PVDF | |||
Pore size | 0.2µm | |||
Support Layers | Polyester | |||
Body and Core | Gamma Stable Polypropylene | |||
Size | ||||
Size |
|
|||
Effective Filtration Area (Nominal) |
|
|||
Dimension (End to End) – ¼” SHB I/O |
|
|||
Dimension (End to End) – ¾” Sanitary Flange Inlet I/O |
|
|||
Dimension (End to End) – Female Luer Lock Inlet/ Male Luer Slip Outlet |
|
|||
Operational Radius (with Vent/ Drain) |
|
|||
Integrity Testing / Retention | ||||
Bubble Point | > 18psi (1.26Kg/cm²) with 50% IPA/ Water Solution | |||
Bacterial Retention | LRV> 7 for B. diminuta per cm² of filter area as per ASTM F 838 | |||
Operational | ||||
Max. Operating Temperature | 80° C @ < 0.5 Kg/cm² (7psi) | |||
Max. Differential Pressure | 1.5 Kg/cm² (22 psi) @ 30° C | |||
Sterilization By Irradiation | Gamma Irradiatiable up to 50 kGy. These filters should not be autoclaved or in-line steam sterilized. | |||
Assurance | ||||
Toxicity | Passes Bioreactivity test, In Vivo, as per USP <88> for Class VI plastics | |||
Bacterial Endotoxin | Aqueous extracts exhibit < 0.25 EU/ml as established by Limulus Amebocyte Lysate (LAL) Test as per USP <85> | |||
Bioburden | Bioburden level is < 1000 cfu/filter device as per ISO 11737-1 : 2018 | |||
Non Fiber Releasing | Passes test as per USP and comply with USFDA 21 CFR Part 210.3 (b)(6) for fiber release | |||
Indirect Food Additive | Comply with USFDA 21 CFR Part 177.1520 | |||
Good Manufacturing Practice | These products are manufactured in a facility which adheres to Good Manufacturing Practices | |||
Oxidizable Substances | Within limits as specified in USP <1231> | |||
Particle Shedding | Passes USP test for particulates in injections | |||
Quality Management System | ISO-9001 Certified | |||
USFDA | DMF No. 015554 |
AseptiVent®- VF- γ 25mm
|
|
|
|
|
|
|
|
a: Gamma sterilized filters cannot be gamma irradiated again
**Female Luer Lock is available as Inlet only
***Male Luer Slip is available as Outlet only
Example :
IVFX | 06 | 01 | MN | R | X | 1 | 04 |
Example for Non Sterile: IVFX0601MNRX104 Example for Gamma Sterile: IVFX0601MNXX304
AseptiVent®- VF- γ (37mm, 50mm)
|
|
|
|
|
|
|
|
a: Gamma sterilized filters cannot be gamma irradiated again
*37mm is available with ¼” SHB I/O connection and in pack size 20 only
Example :
IVFX | 08 | 01 | BB | R | X | 1 | 08 |
Example for Non Sterile: IVFX0801BBRX109 Example for Gamma Sterile: IVFX0801BBXX309