capsule filters, filters, 0.2µm AseptiCap® KSO-γ 1", 2", 5", 8", 0.2 KSO, DKOX, DKO5
- Wide pH compatibility (1-14)
- Absolute retention
- Low protein binding
- Light weight and self supporting
- Low hold up volume
- Very high flow rates
- 100% Integrity tested
- Total traceability
- Scale up of new drug delivery systems
- Bioburden removal from cell harvest supernatants
- Sterilization of bio-pharmaceuticals such as vaccines and therapeutic proteins
- Sterilization of oncology drugs
- Sterilization of buffers
Construction |
Membrane |
Polyethersulfone |
Final Filter Pore Size |
0.2µm |
Filter Media |
Polyethersulfone Membrane |
Support Layers |
Polypropylene |
Housing |
Polypropylene |
Size |
Size |
|
Effective Filtration Area (Nominal) |
250cm² | 500cm² | 1000cm² | 2000cm² |
|
Dimension (End to End) - ½" Hose Barb I/O |
|
Dimension (End to End) - 1½" Sanitary Flange Inlet ½" Single Step Hose Barb Outlet |
|
Dimensions (End to End) - ¾" Sanitary Flange I/O |
|
Dimension (End to End) - 1½" Sanitary Flange I/O |
|
Dimension (End to End) - ½" Single Step Hose Barb I/O |
|
Operational Radius (with Vent/ Drain) |
|
Vent and Drain |
¼" Hose Barb with Silicone "O" rings for 2", 5" and 8" only |
Integrity Testing / Retention |
Bubble Point |
> 50psi (3.52Kg/cm²) with Water |
Operational |
Max. Operating Temperature |
80 °C @ ≤ 2 Kg/cm2 |
Max. Differential Pressure |
4 Kg/cm2 @ 30 °C |
pH Compatibility |
Compatible with pH range of 1-14 |
Sterilization By Irradiation |
Gamma Irradiatiable up to 50 kGy. These filters should not be autoclaved or in-line steam sterilized. |
Shelf Life |
3 years after gamma sterilization |
Bacterial Retention |
LRV > 7 for B. diminuta ATCC 19146 per cm² of filter area |
Assurance |
Fiber Release |
Complies with USFDA CFR Title 21,210.3 (b) (6) |
TOC and Conductivity |
Meets the WFI requirements of USP <643> for Total Organic Carbon after a 3 liter WFI flush and <645> for Conductivity after a 3 liter
WFI flush |
Particle Release |
The filtrate complies with USP <788> test for particulate matter in injections |
Oxidizable Substances |
Passes test as per USP |
Quality Management System |
ISO-9001 Certified |
USFDA |
DMF No. 015554 |
Biosafety |
Passes Biological Reactivity test, In-Vivo, as per USP <88> for Class VI plastics Passes the Biological Reactivity Tests,In Vitro for Cytotoxicity as described in USP <87> |
Type | AseptiCap® KSO-γ (0.45 μm Upstream)
| DKOX | AseptiCap® KSO-γ (0.8 μm Upstream)
| DKO5 | | Size | | EFA | Code | 1" | 100 cm2 | 31 | 250 cm2 | 51 | 2" | 500 cm2 | 52 | 5" | 1000 cm2 | 53 | 8" | 2000 cm2 | 57 | | Pore Size | Pore Size | Code | 0.2µm | 01 | | I/O Connection | Connection | Code | ¼" SHB | A | ¼” MNPT (18 TPI) | B | ¼” BSP (19 TPI) | M | ¼” BSP (19 TPI) with O-ring | P | ¼” BSP | F | ½” MNPT | C | ½” Hose Barb | D | 1½" Sanitary Flange | E | ¾" Sanitary Flange | S | Quick Connector | J | Single Step ½” Hose Barb* | Q | Female Luer Lock | U | Male Luer Slip** | W | 3/8" Hose Barb* | I | 3/16" Hose Barb*** | N | | Radiation Sterilizable | | Code | Yes | R | No**** | X | | | Sterility | | Code | Non Sterile | 1 | Gamma Sterile | 3 | | Pack Size | Pack Size | Code | 1 | 01 | |
*1” Capsule Filters are not available with ½” Single Step Hose Barb and 3/8" Hose Barb
**Male luer slip is available only in 1” capsule filter as outlet
***3/16" Hose Barb end connection is available in:
- 1" and 2" capsule filters as inlet and outlet
- 5" capsule filters as outlet only
****Gamma irradiated capsule filters cannot be gamma sterilized again
Example :
Example for Non Sterile: DKOX5701EERX101 Example for Gamma Sterile: DKOX5701EEXX301